No hot water from gas water heater
Fix it nowSeven steps
- Before you start: Keep sealed covers on; leave the piping and wiring alone.
- Never light the pilot with matches; use its igniter.
- Read the heater's label; check the pilot flame or light code.
Why
Codes and lighting steps differ by model; don't remove covers. - Pilot out? Relight it only by its label, with its igniter.
Why
Follow every labeled waiting period; never improvise with matches. - No clear instructions, or sealed covers to open? Don't relight it.
Why
Automatic-ignition heaters must not be lit by hand.
The other four steps
- After heavy use, wait for the tank to heat up again.
Why
Demand may have exceeded the tank's capacity. - Try hot water at two faucets. Keep your hand out at first.
Why
One cold fixture points toward its mixing valve. - Check the dial. Use the manual's setting, never above 120°F.
Why
Higher settings increase scald risk. - One try fails, or the water stays cold? Stop; call a plumber.
Why
Further ignition or control troubleshooting requires qualified service.
When to stop
Stop and get a plumber if:
Gas smell or hissing: leave now; don't touch switches. Call 911 and the gas company from outside.
CO alarm: get everyone out; call 911 from outside. Headache, dizziness or nausea: get outside; call Poison Control, 1-800-222-1222. Someone unconscious, not breathing, or struggling to breathe: call 911 now. Don't go back in.
Soot, a damaged vent or a damaged viewing window: stop using the heater; call a plumber now.
The pilot fails once, goes out again, or shows a fault code: stop; call a plumber.
It would mean touching gas valves, wiring or sealed covers: stop; call a plumber.
What it probably is
Tank depleted by heavy useWater turned cold after several showers or laundry loads.You can check
Standing pilot went outNo pilot visible through the intact viewing window; check the heater's label.You can check
Ignition, flame sensor, or gas control failurePilot will not stay lit, or status light shows a fault.For a pro
Faulty faucet or shower mixing valveOther faucets get hot; only one fixture stays cold.For a pro
Time and parts
- Parts
- $0; checks only, no replacement parts
Fair price, if a pro does itTyler & Longview
$850–1,925per job
Get it done
More than a quick fix? Vora gets quotes privately and recommends one plumber.
The plumbers we’d call in Tyler & Longview · No hot water: what to do
Checked against
- Atmos Energy — Natural Gas Safety Guide
- Manufacturer — Residential Gas Water Heater Troubleshooting
- HRSA Poison Help — Carbon Monoxide
- Poison Control — Carbon Monoxide