Heating and air · checked 7 Oct 2026
The AC is running but not cooling
Fix it nowEight steps
- Before you start: If the house gets dangerously hot, move everyone somewhere air-conditioned.
- Confusion or collapse in heat: call 911; cool them with wet cloths.
- See ice on the lines? Turn cooling off; let it thaw.
- Ice on the lines? Turn cooling off; let it thaw fully first.
Why
The fan, a clean filter and open vents help it melt; never chip it or use heat. Ice again after a full thaw: call an HVAC tech. - Thermostat off, fan on Auto. Wait until the blower stops.
Why
Stop airflow before handling an accessible filter. - Swap a dirty filter, same size; its arrows point toward the duct.
Why
Restore airflow; skip filters requiring equipment covers or unsafe access.
The other five steps
- Open the vents; move furniture away from vents and return grilles.
Why
Blocked airflow can reduce cooling and cause freezing. - Set the thermostat to Cool, fan Auto, two degrees below the room.
Why
Make sure the thermostat actually requests cooling. - Wait 15 minutes. Is the air from the vents cooler?
Why
Allow startup delays; avoid repeatedly switching the system. - Still warm? Turn cooling off and call an HVAC tech.
Why
Refrigerant and electrical repairs require a trained technician. - Hotter inside? Move to air-conditioning; children and vulnerable adults first.
Why
Children, older adults, and medically vulnerable people face greater heat risk.
When to stop
Stop and get a heating and air technician if:
Ice comes back after a full thaw: leave cooling off; call an HVAC tech.
Water leaks around the indoor unit: stop using it; call HVAC.
A breaker trips: stop troubleshooting; do not repeatedly reset it. Call HVAC.
Someone becomes confused, collapses, or has slurred speech in heat: call 911; cool with wet cloths.
Still warm after these checks: turn cooling off; call HVAC.
What it probably is
Incorrect thermostat settingsCOOL is not selected, or the setpoint exceeds room temperature.You can check
Restricted airflowThe filter is visibly clogged, or furniture blocks vents or returns.You can check
Frozen indoor coilIce appears on exposed refrigerant lines; airflow may weaken.For a pro
Refrigerant leakCooling stays poor despite correct settings and a clean filter; ice may appear.For a pro
Compressor or electrical-control failureIndoor air blows, but outdoor equipment stays silent during a cooling call.For a pro
Time and parts
- Time
- Estimated 20–30 minutes for basic checks. Ice can take several hours to thaw.
- Parts
- $0–$30 for no parts or a typical disposable filter; specialty filters cost more.
Get it done
More than a quick fix? Vora gets quotes privately and recommends one heating and air technician.
Checked against
Written for Vora from these public sources and checked on 7 Oct 2026. General guidance, not a substitute for a pro on site. In danger, leave and call 911.